UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof

UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof

Brand Name: SZ
Model Number: EVA
MOQ: 10.000 square meter
Price: $0.3-$2.0/SQM
Supply Ability: 10.000 square meter per day
Detail Information
Place of Origin:
CHINA
Certification:
ISO
Product Name:
EVA Waterproof Membrane
Material:
EVA / PE
Function:
Waterproofing
Application:
Metal Concrete Wood Terrace Roof
Thickness:
0.8-3mm
Surface:
Both Side Smooth
Standard:
ISO, GB,ASTM
Color:
Black
Packaging Details:
Packed in woven bag or your requirements
Supply Ability:
10.000 square meter per day
Highlight:

UV Resistant EPDM Waterproof Membrane

,

60mil Thick EPDM Waterproof Membrane

Product Description

High Quality UV Resistant 60mil Thick TPO Rubber Roof Waterproof Membrane For Metal Concrete Wood Terrace Roof

 

EPDM waterproof membrane is made from ethylene propylene diene monomer (EPDM), adding into some chemical auxiliaries, for example,carbon black, nanophase modifier, plasticizer, vulcanization accelerator and others, it is one kind of polymer waterproof membrane with excellent performance elasticity.

 

Name
EPDM geomembrane
Thickness
0.8mm 1.0mm 1.2mm 1.5mm 2.0mm
Width
1m- 8m
Length
20m, 50m-200m/roll or customized
Color
Black, White, Blue, Green or Customized
Surface
smooth or textured
Features
1. It has excellent environmental stress cracking resistance and excellent chemical corrosion resistance.
2. Excellent chemical resistance.
3. Has a large operating temperature range and a long service life.
4. High tensile strength and elongation

 

 

 

 

 

UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 0 UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 1

UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 2UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 3

 

 

Waterproof membrane thickness selection

 

 

Key factors affecting thickness selection

 

1. Waterproof ability and durability

  • Thickness determines the ability of the roll to resist water pressure and puncture. For example: 1.5mm roll is suitable for conventional roofs, while underground projects require ≥2.0mm to resist soil side pressure.
  • Thicker rolls (≥3.0mm) are more resistant to aging, but too thick may cause self-weight sliding or hollowing.

2. Environmental adaptability

  • Temperature influence: High temperature areas (such as South China) need to choose high temperature resistant APP modified asphalt roll (softening point 160℃), low temperature areas (such as Northeast China) need SBS elastomer modified roll (resistant to -25℃).
  • Environmental coefficient formula
  • Open roof: +0.3mm
  • Basement: +0.5mm
  • Planted roof: +0.8mm (resistance to root puncture).

Thickness standards of different materials

 

1. PVC waterproofing membrane

  • Conventional thickness: 1.5mm (minimum value 1.35mm, average value ≥1.5mm).
  • Allowable error: ±0.3mm (such as 3.7mm~4.3mm).

 

2. TPO waterproofing membrane

  • Common thickness: 1.2mm, 1.5mm, 2.0mm, customizable.

 

3. SBS/APP modified asphalt membrane

  • Conventional thickness: 3mm, 4mm, 5mm, polyester base is better than composite base.

 

4. Self-adhesive membrane

  • Recommended thickness: above 2.0mm, ensure that the base layer is flat to avoid hollowing.

UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 4UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 5UV Resistant 60mil Thick EPDM Waterproof Membrane For Metal Concrete Wood Terrace Roof 6

 

Scenario-based recommended thickness

 

1. Roofing project

  • Cold areas: SBS modified asphalt roll (3mm~4mm).
  • Hot areas: APP modified asphalt roll (3mm~4mm) or TPO roll (1.5mm~2.0mm).

2. Underground project

  • Self-adhesive roll (2.0mm~3.0mm) or PVC roll (1.5mm~2.0mm).

3. Green roof

  • ≥2.0mm, and add a root puncture resistance layer (such as EPDM roll).

 

Quality identification and construction points

 

1. Quality inspection

  • Check the base (polyester felt is better than composite felt) and the uniformity of cross-section impregnation.
  • Check the test report (such as GB 18242 standard).

2. Construction adaptation

  • Temperature control
  • Modified asphalt roll: The best construction temperature is 10~25℃, and the roll is preheated to 50~60℃ at low temperature.
  • Self-adhesive roll: Construction at 5℃~40℃, the activity of the adhesive layer changes significantly with temperature.
  • Overlap treatment: Thick rolls need to accurately control the melting depth to avoid step effects.

3. Environmental protection and standards

  • Avoid using composite tires and recycled materials (listed as restricted).
Product appearance
Color
Black
Visible defects
No defects, conform to EN 1850-2
Technical specification
WENRUN EPDM
Item
Standard
Unit
VRH1200
Thickness
EN 1849-1,
mm
1.2(-5/+10%)
Length
EN 1848-1
m
20(-0.5/+0.5%)
Width
EN 1848-1
m
2.0(-1/+1%)
Mass per unit area
EN1849-4
Kg/m2
1.44(-5/+10%)
Tensile strength
EN12311-2,
N/mm2, ≥
8
Elongation at beak
EN12311-2,
%, ≥
500
Joint shear strength
EN12317-2
N/50mm, ≥
500
Tear resistance
EN12310-2,
N, ≥
30
Dimensional stability
EN 1107-2,
%, ≤
0.5
Cold flexibility
EN 495-5
-45, No crack
Static loading resistance
EN 1110
kg
25
Impact resistance
EN 12691
mm, ≥
300
Watertightness
EN1928B
--
PASS
UV-resistance
EN 1297
Grade 0
PASS
Fire-resistance
EN13501-1
--
Class E